Moving and lifting Power Unit

Power Unit owner's manual

Warning

Do not go under the unit when it is lifted.

Caution

Use all lifting lugs of the unit when you lift it. Minimum angle of slings 60 degrees.

Caution

High center of gravity. Make sure that the cabinet does not fall over.

Caution

The module rails inside the cabinet have sharp edges. Be careful when removing and installing modules.

Notice

The maximum tilting angle of the charging power unit is 6 degrees.

Notice

One cabinet with four Power Modules weighs approximately 400 kg. Use appropriate lifting equipment, e.g. a forklift, operated by qualified professionals.

Notice

Carefully remove the control module, the dynamic power distribution module, the bottom Power Module, and the front panel of the mains module from each cabinet before you lift the unit. This is done to reduce the weight and make space for installing the cables. Keep the modules clean and dry.

Notice

Make sure that you replace the control module to the same cabinet that it was removed from. Each cabinet is identified with its unique serial number in ChargEye. Interchanging the control modules between cabinets will cause configuration errors.

Notice

Do not lift Power Module from its guide pins.

Note

The Power Module weighs approximately 43 kg.

Note

The dynamic power distribution module weighs approximately 32 kg.

Note

Remove the tilt indicator before you start the installation.

Note

Use all the lifting lugs to lift the unit. See the lifting lugs on a single, double, and triple cabinet.

PU_lifting_points
  1. Remove the bottom modules before you lift the unit.

    Note

    For double and triple cabinet installations, we recommend marking the control modules as you remove them to prevent installation in the wrong cabinet.

    PU_remove_bottom_modules
  2. Make sure not to exceed the maximum tilting angle of 6 degrees.

    PU_V3_max_tilt.svg
  3. Use all lifting points if you use lifting beams.

    Note

    Lifting beams are not included in Kempower's delivery.

    PU_lifting_beam
  4. Lift the unit to be installed. Left: without the steel base. Right: with the steel base.

    Notice

    When the unit is in place, do not remove the lifting lugs. The lifting lugs secure the roof in place and prevent water from getting inside the unit.

    PU_V3_lifting_cabinet.svg