Danger
Electric vehicle charging equipment must be located at a safe distance from potentially explosive atmospheres. Know and obey local laws and regulations.
Notice
The site plan is the customer's responsibility. Kempower does not provide plans for individual installations.
Notice
Branding according to Kempower Customer Branding Guidelines. Applying additional painting or stickers by the customer to Power Unit, Power Cabinet Version 3, unless specifically agreed upon with Kempower, will void the warranty.
Note
Fastening hardware for installing the units to the installation surface is not included in the Kempower delivery.
Note
See the product datasheets for the dimensions and weights of the units, available at Kempower Mediabank.
Note
For information on Kempower DC charging points, see Kempower user manuals, available at Kempower Mediabank.
Note
For more detailed site planning information, see Kempower site planning guidelines, available at Kempower Mediabank.
As the requirements of individual installations vary significantly, it is not possible to give detailed instructions that are valid for all sites. Take into account at least the following general issues when you plan the layout of the electric vehicle charging site:
The local rules and requirements on civil works, electrical installations, cable routing, and cable dimensioning. Cable dimensioning is the electrical designer's responsibility. For assistance, contact Kempower Solutions Support.
When you determine cable lengths:
Leave an additional 1000 mm of supply power cable length above the installation surface.
Consider how the units are moved to and within the installation site. The maximum allowed tilting for the charging power units is 6 degrees.
The installation surfaces of the site:
The units can be installed directly on a flat, level, and solid surface that can withstand the weight of the unit, or on concrete foundations that are prefabricated or made on site. See Concrete foundations.
The specific requirements and ambient conditions of the site:
If you plan to install the charging power unit in a closed space, contact Kempower Solutions Support to approve the location before installation. If the unit is installed indoors, make sure that the air flow to the unit is sufficient.
If the temperature stays above 30 °C for long periods of time, we recommend placing the charging power unit in a well-ventilated shelter. For assistance, contact Kempower Solutions Support.
Operating temperature:
Charging power unit −30…+55 °C
Storage temperature:
Charging equipment −40…+60 °C
The location of the main supply point: supply grid main distribution board or one of the secondary substations.
The configuration of your communication system:
Connectivity to ChargEye and possible OCPP backend system requires an Internet connection, either with a SIM card (nano) or Ethernet (shielded Category 6 cable suitable for wet locations) cabling to your wide area network (WAN) router.
The correct ports need to be open for communication. See Table 5, “Ports for ChargEye connectivity”.
The units must be easily accessible for maintenance without disturbing traffic or other movement in the charging area.
The maximum distance between the charging power unit and a connected charging point is approximately 80 m.
In MORE Power charging systems the maximum distance between two parallel connected Power Units is approximately 10 m. The minimum distance is 20 mm between units and, for Power Unit, Power Cabinet Version 4, 160 mm between the units' foundations.
The Kempower delivery includes the charging equipment and cabling inside the units. Cabling from the AC main power supply to the unit(s), all cabling between the units, and any other components are the customer's responsibility.
Port number | Service/Protocol | Direction |
|---|---|---|
53 | DNS/UDP | outward |
123 | NTP/UDP | outward |
22 | SSH/TCP | outward |
443 | HTTPS/TCP | outward |